| Waterheatertimer.org is a self-help site |
Compare 16 electric and 2 gas water heater timers | Try a water heater timer free | Figure Volts Amps Watts for water heater | 9 ways to save with water heater | Troubleshoot electric water heater | Do-it-yourself | ||
|
||||||||
Wire T1906 and T1905 timers![]() |
Wire T-101 T103 T104 timers ![]() |
Wire
EH40 and WH40 timers![]() |
Tork timers and manuals![]() |
In-wall programmable timers![]() |
|
Paragon
timers and manuals |
![]() Larger image of trippers and pins Order replacement parts and tripper numbers Invensys is still making Paragon defrost timers, but Kidde Safety who purchased Paragon is not making Paragon timers or parts Nov 22, 2010 |
|||||
![]() |
P-100
48 on-off per 24-hour day 30 minute minimum, 23-1/2 hour maximum Skip-a-day feature Hasp for padlock Nema1 indoor metallic or NEMA3 exterior non-metallic Shipped with 2 sets X9242 trippers P-100 Sell sheet with models and wiring P-100 install manual Uni-line wholesale |
![]() Larger image |
||||
| Extra X9242 trippers for P100 | ||||||
![]() Paragon 1015 image |
Paragon
1015 series 24-hour repeat timer; Skip-a-day feature; 10-16 ga wire Never-lose trippers on dial 96 trippers; 48 on-off per day; 15 minute intervals NEMA 3 outdoor metal enclosure; Hasp for padlock Two load capability with NO and NC terminals 3 watt consumption Paragon 1015 sell sheet shows models and wiring Paragon 1015 install-operation manual explains NO NC terminals and skip-a-day 1015-00RS at Uni-line wholesale 1015-4OTS |
![]() |
||||
| Clock motors | ||||||
![]() |
Paragon
4000 do
not confuse with EC4000
shown below Uses Paragon X2772 tripper 24 hour timer with 7 on-off operations per day 1-1/2 hour minimum period Accepts up to 8 gauge wire NEMA 1; NEMA 3R; NEMA3 for all environments 120V and 208-277V choices DPSP and SPST choices Different models offer skip-a-day & Astro-dial for seasonal adjustments Paragon 4000 installation manual with wiring 4000 Series install/operation manual Paragon 4000, 4010, 4200 series model numbers and wiring 4000 at Uni-line wholesale |
![]() |
||||
|
||||||
![]() |
Paragon
7000 do
not confuse with EC7000 shown below X4299 tripper 24V, 120V, 208-277V 7 day timer, 4 on-off per day Different schedules for each day HVAC, fans, motors. NEMA1 indoor enclosure. Single phase and 3 phase loads 3 hour minimum time period Controls 4 separate loads >> each on same time schedule Accommodates up to 8 gauge wire Choice of 4-pole-4NO & 2NO-2NC Sell sheet with models and wiring diagrams Paragon 7000 and 7210 series manual with models and wiring Paragon 7000-00 120V wiring manual 7000 at Uni-line wholesale |
![]() |
||||
| 7000 series Clock motors: 120V 60Hz M3099-00 208-277 60Hz M3193-71 24V 60Hz M3102 |
![]() 4 relays can be wired to control any voltage Example wiring 4PST |
![]() 4PST wiring diagram Larger image |
||||
![]() |
Paragon
44000 series Paragon 44005-00 24-hour timer repeats same on-off each day Paragon 44001-00 Repeats 1 to 7 events every 4 hours 3 watt power consumption 120Volts; 8 gauge wire; SPST; NENA 1 indoor box Paragon 44005 Manual Paragon 44001 manual |
![]() |
||||
| Digital timers | ||||||
![]() |
Paragon
EC7000 7 day digital timer 16 events per 7-day week, allows different schedule each day NEMA 1 (indoor) and NEMA 3R (outdoor) enclosures 1-59 second duration; Day skipper Power outage capacitor carryover without battery 4 watt power consumption Paragon EC 7000 Sell sheet model numbers EC7000, EC7004, EC7005 wiring/ programming Paragon EC 7000 manual with model numbers and wiring EC7000 at Uni-line wholesale |
![]() |
||||
| EC7000120V EC7000PC120V-RT EC7001PC12Vdc EC700024V |
EC7000
Model numbers and descriprtion
EC7000208-277VEC7001120V EC7001208-277V |
EC7004120V EC7004208-277V EC7005PC120-240V |
||||
![]() EC4005 image |
Paragon
EC4000 Non-metallic NEMA type 3R indoor/outdoor enclosure 24 hour digital timer with skip a day 16 events per 24 hour Controls single 240 Volt load Up to 10 gauge wire Power outage capacitor carryover without battery Paragon EC 4000 sell sheet shows model numbers and wiring Paragon EC 4000 programming manual Paragon EC 4000 manual shows model numbers and wiring EC4000 at Uni-line wholesale |
![]() Larger image |
||||
![]() |
Paragon
EL71-EL72 EL71 single channel timer EL72 2-channel controls 2 separate on-off times EL74 4-channel timer (quad control) EL712 12-channel timer 24 hour, 7 day or 365 day timer 96 hour capacitor carryover in power outage Durations from 1 second to 23 hour 59 minute 59 second, Sell sheet shows EL71 EL72 models and wiring Paragon EL71 EL72 manual with programming Paragon EL712 12-channel timer programming Paragon EL74 programming Paragon EL78 8-channel programming manual EL74 EL78 EL712 sell sheet Paragon EL74 EL78 EL712 manual with model numbers and wiring |
![]() |
||||
| Page with model numbers EL71120V EL71208-240V EL71277V |
EL71PC120V EL71PC208-240V EL71PC277V EL72120V |
EL72-208-240V EL72-277V EL72PC120V EL series controls at Uni-line wholesale |
||||
![]() |
Paragon
42000 24-hour time clock 98 self contained trippers for 48 operations per day 15 minute minimum time/ 24 hour clock 120V and 240V models NEMA3 metal enclosure rain-tight with hasp for lock Simple wiring Paragon 42000 sell sheet shows model numbers and wirings diagrams Uni-line wholesale |
![]() |
||||
![]() |
Paragon
8025 Time increments from 60 seconds to 27-1/2 minutes 2 hour minimum between operations 12 on-off per day, minimum 2 hours between operations NEMA 1 (indoor) and NEMA 3R (outdoor) enclosures Multiple electrical loads 690Watts per terminal; 10-16 gauge wire 2 NO contacts, 1 NC contact 8025-00 120V NEMA1 indoor 8025-00P 120V NEMA3 outdoor non-metallic 8025-20 208-204V NEMA1 indoor Image of 8025 wiring Paragon 8025 Sell sheet with model numbers and wiring 8025 series at Uni-line wholesale |
![]() |
||||
| 8025 Clock motors: 120V 60Hz M1129-00 208-277 60Hz M1130-20 |
||||||
![]() |
Paragon
EC365DST Sun Tracker Dusk to dawn timer for 120Volt or 240Volt loads Set timer to track exact times, or set amount of time before or after EC365 Sell sheet with model numbers and wiring diagrams EC365 Manual with programming instructions Paragon Astro dial |
![]() |
||||
![]() |
EC74 4 channel timer Controls 4 separate Load with different schedule for each. 50 event programming 365 day Momentary 1-59 second feature for bell ringing applications 9 volt battery back-up NEMA3 outdoor enclosure 32°-122° operating temp EC74 Manual: install and programming EC 74 4-channel timer EC128 manual not found EC74 at Uni-line wholesale At Paragon |
![]() Larger image shows 4-channel wiring |
||||
EC7450S120 description 100-120V 4-channel-SPDT EC7450S24 description 24Volt 4-chanel-SPDT EC7450S240 description 240V 4-channel-SPDT |
EC EL Series model comparison sell sheet | |||||
![]() EL7100 |
EL7100
1-channel timers 24-hour, 7-day, or 356 day/ Daylight savings. One channel 128 ON/OFF NO NC terminals Momentary option for latching relays 90 holiday days for versatile programming Operating temperature -20° to 140°F (-29° to 60°C) 4 Watt power consumption EL7100 and EL7200 timer manual EL7100 series at Uni-line wholesale |
![]() |
||||
| EL7100 ans 7200 description pages: EL7100120V EL7100208-240V EL7100PC120 |
EL7100PC208-240V EL7200120V EL7200208-240V |
EL7200PC120V EL7200PC208-240V |
||||
![]() EL7200 |
EL7200
2-channel timer 24-hour, 7-day, or 356 day/ Daylight savings. Maintained or momentary 12 hour or 24 hour format Dual NO NC terminals EL7100 and EL7200 timer manual |
![]() Larger image |
||||
![]() EC71D |
Paragon
EC71D EC71/18S and EC71D/18S are 365-day single channel, microprocessor-based time controls, used for switching electrical circuits according to pre-set time program. Use with lighting, heating, ventilating, air conditioning, motors, pumps, fans, bells, security systems, traffic intersection lights, school flashers, or any load with a time-of-day schedule. Programmable momentary option provides a 1 to 59 second momentary contact closure for applications as ringing school bells, church chimes, and operating latching relays. EC71 EC71D manual |
![]() |
||||
![]() EC72D |
Paragon
EC72D EC72 and EC72D are seven-day, two-channel time controls that switch two different circuits according to set program Daylight Savings Time, adjusting for Leap Year and altering ON/OFF events on designated holidays. Control indoor and outdoor lighting, heating, ventilation and air conditioning, and motors, pumps and fans in convenience and retail stores, commercial buildings, industrial facilities, schools and churches. The Momentary Option, accessed by clipping jumper wire, provides two-second momentary contact closure for ringing school bells and church chimes or operating latching relays. The 12-volt DC model is for battery-powered applications such as security systems, remote deer feeders and air sampling machines. EC72 EC72D manual Replace with 2-channel Intermatic ET70215 Read replacement pdf |
![]() |
||||
![]() |
Paragon
EC11D 120Volt 1 SPDT relay with 288 on-off 24-hour Paragon EC11D manual |
![]() |
||||
| EL71 EL72 two channel EL72 2 SPDT relays EL71 1 DPDT relay |
||||||
| EL74 4-channel 4 SPDT |
||||||
| EL78 8 SPDT relays EL712 12 SPDT relays |
||||||
![]() |
Paragon
E500 interval and delay timers E-500 series sell sheet Paragon E500 at Uni-line wholesale See Dayton Off Delay timer |
![]() |
||||
| Defrost
timers Uni-line commercial defrost timer page Defrost timer training pdf Invensys Training page Commercial refrigeration systems pdf |
These timers are single phase 120V and
240V Clock motors are single phase 120V and 240V |
|||||
![]() Larger image |
Paragon
9045 & 9145 Universal defrost timer Made in the USA Multi-voltage timer: 120V 208V 240V no jumper or switches 100 hours power loss retention for time and defrost Mechanism-only will fit standard Paragon enclosure Operation 6Watts Paragon 9145 sell sheet manual with models, specs, wiring, and conversion wiring diagrams At Uni-Line ![]() |
The 9045 and 9145 Universal defrost
timer manual has cross-over wiring for converting 8045 and 8145 to
the universal timer. But manual does not show cross-over wiring between 8045 and 8145. |
||||
![]() |
Paragon
8145 Defrost timer Image of 8145 Wiring Image of 8145 to 9145 conversion wiring Paragon 8000 series sell sheet Paragon 8041, 8045, 8047, 8141, 8143, 8145 with description model numbers and wiring diagrams including Paragon 8145 manual X-3596 tripper 8100 series at Uni-line Defrost timer training |
|||||
Sample Paragon wiring for 8045-20 |
Sample Paragon wiring for 8145-20 | |||||
| Defrost
timer wiring The 8045-20 is for 'Electric Heat Defrosting' Time initiated, time terminated The 8145-20 is for 'Hot Gas Defrosting' Time initiated, pressure or temperature terminated with back up time termination 4-110 minutes The 9045 and 9145 Universal defrost timer manual has cross-over wiring diagrams for converting 8045 and 8145 to the universal timer. Manual does not show cross-over wiring between 8045 and 8145. |
![]() Larger image |
![]() Larger image |
||||
| Other
defrost timers http://www.uni-line.com/m Wiring diagrams: 632 series RM series 8408 series 8025 series 8140 series 8040 series 8408 dimensions and wiring Frost King/Intermatic/Grasslin defrost timers and manuals Buy at Intermatic Intermatic timers and manuals |
8045
defrost cycle works like this: Time initiated, time terminated Timer is running and relay is OFF. Dial rotates continually. Refrigeration compressor is ON. Terminal 4 has power. Refrigeration compressor is ON. Trippers on dial switch relay ON, defrost cycle begins. Terminal 4 has no power. Refrigeration compressor/fan turns OFF. Terminal 3 has power: Heat defrost turns ON. Timer setting from 4 to 110 minutes determines when defrost cycle ends. Timer switches relay off. Defrost cycle ends. Timer is again running but switched OFF Terminal 4 has power. Refrigeration fan turns ON again. Terminal 3 has no power. Heat defrost turns OFF |
8145
defrost cycle works like this: Time initiated, pressure or temperature terminated Timer is running and relay is OFF. Dial rotates continually. Terminal 4 has power: Refrigeration compressor/fan is ON. Trippers on dial switch relay ON, defrost cycle begins. Terminal 4 has no power. Refrigeration compressor/fan turns OFF. Terminal 3 has power: Hot gas/ electric heat defrost turns ON. Temperature-or-pressure switch connects to terminals N - X When temperature-or-pressure limit switch reaches trip point, it closes contacts to solinoid located inside timer that switches timer relay OFF. Defrost cycle ends. Timer relay is switched OFF. Terminal 4 has power. Refrigeration fan turns ON again. Terminal 3 has no power. Hot gas/ electric heat defrost turns OFF. 1 to 6 cycles per day, minimim 4 hrs between cycles Back-up timed defrost termination 4 to 110 minutes How to test 8145-20 timer |
||||
![]() Larger image |
Intermatic Defrost timer Intermatic timers and manuals Time initiated, temperature, pressure or time-terminated DTMV40 defrost timer DTQMV 40 with 7-day back-up battery Dip-switch setting for 120V 208V 240V 40 amp 120V 1HP 240V 2HP Up to 8 gauge wire 1-24 timing actions per day/ 15 minute to 180 defrost duration Mechanism fits into Paragon enclosure DTMV40 Instruction manual with crossover wiring Defrost timer sell sheet with model numbers At Intermatic |
![]() Intermatic Defrost Timer wiring terminals Same as Paragon 8145-20, except with additional F terminal Intermatic timer can be programmed and wired to crossover from ANY paragon defrost timer. |
||||
![]() Larger image |
8000
series Defrost timer Time initiated - time terminated; Termination 4 - 110 minutes 8041-00 120V Electric heat defrosting: 1-3 open 2-4 closed 3-N closed 8041-20 208-240V Electric heat defrosting: 1-3 open 2-4 closed 3-N closed 8045-00 120V Electric heat, hot gas, compressor shutdown defrost: 1-3 open 2-4 closed 3-N none 8045-20 240V Electric heat, hot gas, compressor shutdown defrost 1-3 open 2-4 closed 3-N none 8047-00 120V Electic heat defrosting 1-3 open 2-4 open 3-N closed 8047-20 240V Electric heat defrosting 1-3 open 2-4 open 3-N closed Paragon 8000 series sell sheet with wiring and model numbers |
![]() |
||||
![]() Larger image Larger image2 |
Paragon 8245-00 120V
defrost timer Paragon 8247-20B 208-240 Paragon 8245-20 208-240V 40Amp, KO on top Time Initiated Pressure Terminated Back up time terminated protects against sensor malfunction, adjustable from 4 to 110 minutes 1-6 cycles per day, 4 hours between cycles Set pressure on timer face Adjustable cut-in pressure setting dial Three contact arrangements for hot gas, electric heat or compressor shutdown defrost. Tripper X-3596 8240 series wiring and dimensions |
![]() Three contact arrangements for hot gas, electric heat or compressor shutdown defrost. 8245-00 120V 1-3 open 2-4 cllosed 3-N none 8245-20 240V 1-3 open 2-4 cllosed 3-N open 8247-20 240V 1-3 open 2-4 open 3-N closed |
||||
![]() Larger image |
632-00 10A 120V defrost
timer 632-20 10A 240V defrost timer 632 series wiring and box dimensions Indoor-outdoor 2NO 2NC Water spray defrost control with Pump Down Drain and Delay cycles 3 minute to 45 minute, 3 minute graduations 1 to 8 cycles per day, 3 hours between cycles |
![]() |
||||
![]() |
Paragon 8025 Time
initiated, time terminated Paragon 8025 Sell sheet with model numbers and wiring |
![]() |
||||
![]() |
Paragon
8408 240Volt Time initiated, temperature or prtessure terminated Back up time termination, 4 to 110 minutes Thre 55 Amp heater contacts plus compressor terminal Size 14 to size 4 wire Suffix B Bracket mount X3596 trippers 1-6 cycles per day, 4 hour between cycles 8408 dimensions and wiring |
![]() |
||||
|
Paragon
ET series countdown timer Use screwdriver and set timer for 1 minute to 18 hours Occupant enters room and activates switch. Switch remains ON for duration of time setting Single-pole and 3-way available Not used for sunlamps or tanning equipment Paragon ET series sell sheet shows models and wiring ET series manual Paragon ET at Uni-line wholesale |
![]() |
||||
![]() |
Paragon
2600 Panel mount countdown timer Dial-type countdown timer 120V or 240V SPST NO NC terminals Paragon 2600 2-load timer wiring Image showing model numbers and times Paragon 2600 manual 2600 Wiring Paragon 2600 at Invensys shows model numbers |
![]() |
||||
![]() |
EC437 EC437120V EC437240V 120Volt and 240Volt models Push button ON Push button OFF Time setting from 1 second to 255 seconds 8 amp and 10 amp capacity power consumption 4 watts EC437120V EC437 Paragon EC437 at Uni-line wholesale |
![]() |
||||
![]() |
Paragon-AMF-500-132-00 Automatic reset timer No paperwork |
Wire clock motor: Hot to terminal 1 and Neutral to unmarked Line wires from breaker connect to terminals 2 and 3 Load wires connect to terminals 3 and 5 |
||||
![]() See larger image |
Paragon
JW series Timer has a 10 minute dial Timer cycle repeats each 10 minutes Turn knob either direction, for example turn knob to 3 Timer will turn on Load for 3 minutes out of every 10 minutes With dairy farm fan: Multiply: number of 1000 pound cows X 250. Divide result by the fan CFM JW series instruction/install manual JW series sell sheet Uni-line wholesale with model numbers |
![]() |
||||
| Clock motors: | ||||||
![]() |
Paragon
EJW percentage timer Left dial: Select time durations from 15 seconds to 24 hours Right dial: choose percentage for ON and OFF times EJW 120V SPDT EJW-M 240V SPDT 20 Amp NO 10 Amp NC Size 4/3/4" X 4-3/4" NEMA 4X indoor panel-mount protects against dirt-dust-splashed water E501 is ON delay timer E502 is OFF delay timer EJW sell sheet with model numbers and wiring Uni-line wholesale |
![]() |
||||
| Paragon EC128 | Energy monitoring system | |||||
Paragon replacement mechanisms at Uni-line wholesale Paragon motors at Uni-line wholesale |
||||||
| Paragon
motors 2605-00
timer M1701-00 120V 60Hz Paragon motors 2606-00 timer M1801-00 120V 60Hz |
Paragon
motors 1015
timer M3001-00 120V 60Hz M3074-00 480V 50Hz M3010-00 120V 50 Hz |
|||||
| Paragon
motors 2607-00
timer M1526-00 120V 60Hz M1527-20 208-277V 60Hz |
Paragon
motors 2609-00
timer M4507-00 120V 60Hz Paragon motors 2609-20 timer M4508-20 208-277V 60Hz |
Paragon
motors 2610-00
timer M9801-00 120V 60Hz |
||||
| Paragon
motors 4010
timer M3017-00 120V 60Hz M3191-71 208-277V 60Hz |
Paragon
motors 4000
timer M3017-00 120V 60Hz M3024-06 24V 60Hz |
|||||
EJ500 |
Utilitec |
Woods |
ST01C |
ETW350 |
Aube |
Intermatic |
Sylvania |
Tork |
GE |
Leviton |
Hagar |
Power pack |
![]() Timex |
Countdown |
![]() Larger image |
Intermatic
box timers: How to set box timers Troubleshoot box timers Trippers and parts Intermatic GM series |
![]() |